Vocabulary Hub
01ontology

DATEX II EnergyInfrastructure — EV-charging subset (EONA-X hub-curated)

Version
0.3.0
Namespace
https://vocab.eona-x.eu/datex-ii
Description
Hub-curated SKOS rendering of the DATEX II EnergyInfrastructure model, scoped to EV charging (IRVE) for the EMDS demo: entities, attributes, attribute value types and enumeration code values.

Also available as Turtle · JSON-LD

02Terms

281 terms

Source ratio value

https://vocab.eona-x.eu/datex-ii/sourceRatioValuehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The percentage share of this energy source within the electric energy mix.
Scope note
Value type: xsd:decimal (percentage). DATEX II native type: PercentageValue. Required in DATEX II.

Other energy source (free text)

https://vocab.eona-x.eu/datex-ii/otherEnergySourcehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Free-text description of the energy source when datex:energySource is 'other'.
Scope note
Value type: xsd:string. DATEX II native type: String.

Energy source

https://vocab.eona-x.eu/datex-ii/energySourcehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The type of energy source for this source/ratio pairing. Reuses the pre-existing datex:energySourceType enumeration root (ElectricEnergySourceTypeEnum) as its range rather than duplicating its 10 code values under a new IRI.
Scope note
Value type: enumeration (DATEX II ElectricEnergySourceTypeEnum) — reuses the pre-existing datex:energySourceType enumeration (see its narrower code values). Required in DATEX II.

Electric energy source ratio

https://vocab.eona-x.eu/datex-ii/ElectricEnergySourceRatiohttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A single energy-source/ratio pairing within an electric energy mix (e.g. '40% solar'). Referenced by the pre-existing ElectricEnergyMix entity via the new datex:electricEnergySourceRatio containment attribute; provides a fully faithful, properly-nested alternative to that entity's pre-existing flattened datex:energySourceType/datex:energySourceRatio attributes.

Bike parking capacity

https://vocab.eona-x.eu/datex-ii/bikeParkingCapacityhttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The number of bike parking places in the associated parking.
Scope note
Value type: xsd:nonNegativeInteger. DATEX II native type: NonNegativeInteger.

Truck parking capacity

https://vocab.eona-x.eu/datex-ii/truckParkingCapacityhttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The number of truck parking places in the associated parking.
Scope note
Value type: xsd:nonNegativeInteger. DATEX II native type: NonNegativeInteger.

Car parking capacity

https://vocab.eona-x.eu/datex-ii/carParkingCapacityhttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The number of car parking places in the associated parking.
Scope note
Value type: xsd:nonNegativeInteger. DATEX II native type: NonNegativeInteger.

Associated parking

https://vocab.eona-x.eu/datex-ii/AssociatedParkinghttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Parking capacity associated with an energy infrastructure facility, broken down by vehicle class.

Additional information

https://vocab.eona-x.eu/datex-ii/additionalInformationhttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Free-text additional information about the pricing policy.
Scope note
Value type: xsd:string. DATEX II native type: MultilingualString.

Minimum delivery fee

https://vocab.eona-x.eu/datex-ii/minimumDeliveryFeehttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The minimum fee charged for a delivery under this pricing policy.
Scope note
Value type: object reference (DATEX II Facilities AmountOfMoney; external, out of scope).

Maximum delivery fee

https://vocab.eona-x.eu/datex-ii/maximumDeliveryFeehttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The maximum fee charged for a delivery under this pricing policy.
Scope note
Value type: object reference (DATEX II Facilities AmountOfMoney; external, out of scope).

Discount

https://vocab.eona-x.eu/datex-ii/discounthttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A discount percentage applied to the energy price.
Scope note
Value type: xsd:decimal (percentage). DATEX II native type: Percentage (float).

Combination with parking fee

https://vocab.eona-x.eu/datex-ii/combinationWithParkingFeehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Whether the energy price is combined with a parking fee.
Scope note
Value type: xsd:boolean. DATEX II native type: Boolean.

Other pricing policy

https://vocab.eona-x.eu/datex-ii/pricingPolicy-otherhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A pricing policy not covered by the enumerated values.

Free

https://vocab.eona-x.eu/datex-ii/pricingPolicy-freehttp://www.w3.org/2004/02/skos/core#Concept

Definition
The energy is provided free of charge.

Unknown pricing policy

https://vocab.eona-x.eu/datex-ii/pricingPolicy-unknownhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The pricing policy is unknown.

Flat rate

https://vocab.eona-x.eu/datex-ii/pricingPolicy-flatRatehttp://www.w3.org/2004/02/skos/core#Concept

Definition
A flat rate applies.

Contract

https://vocab.eona-x.eu/datex-ii/pricingPolicy-contracthttp://www.w3.org/2004/02/skos/core#Concept

Definition
Priced according to a contract.

Price per delivery unit

https://vocab.eona-x.eu/datex-ii/pricingPolicy-pricePerDeliveryUnithttp://www.w3.org/2004/02/skos/core#Concept

Definition
Priced per delivery unit (e.g. per kWh, per litre).

Price per charging time

https://vocab.eona-x.eu/datex-ii/pricingPolicy-pricePerChargingTimehttp://www.w3.org/2004/02/skos/core#Concept

Definition
Priced per unit of charging time.

Pricing policy

https://vocab.eona-x.eu/datex-ii/pricingPolicyhttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The basis on which energy is priced (e.g. per charging time, per delivery unit, flat rate, free).
Scope note
Value type: enumeration (PricingPolicyEnum) — see narrower code values. Multi-valued.

Energy pricing policy

https://vocab.eona-x.eu/datex-ii/EnergyPricingPolicyhttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The pricing policy applied to energy delivered at a refill point/station (pricing basis, discounts, minimum/maximum delivery fees), extending the DATEX II Facilities Rates class.

Parking allowed after charging

https://vocab.eona-x.eu/datex-ii/parkingAllowedAfterCharginghttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Whether parking in this vehicle space is allowed to continue after charging has finished.
Scope note
Value type: xsd:boolean. DATEX II native type: Boolean.

Vehicle space

https://vocab.eona-x.eu/datex-ii/VehicleSpacehttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
An adjacent space for a single vehicle, usually directly linked with an electric charging point.

Electric charging point (containment)

https://vocab.eona-x.eu/datex-ii/electricChargingPointhttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The electric vehicle charging point embedded in this piece of equipment.
Scope note
Value type: object reference (DATEX II ElectricChargingPoint) — see the ElectricVehicleChargingPoint entity. Required in DATEX II.

Electric charging equipment

https://vocab.eona-x.eu/datex-ii/ElectricChargingEquipmenthttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A physical unit of electric-vehicle charging equipment, modelled as a DATEX II Facilities SupplementalFacility that wraps a single ElectricVehicleChargingPoint. The DATEX II native counterpart closest to a physical charge point/EVSE unit as distinct from the (Vehicle)ChargingPoint concept itself.

Unattended

https://vocab.eona-x.eu/datex-ii/serviceTypeCode-unattendedhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill point/station is unattended.

Self-service

https://vocab.eona-x.eu/datex-ii/serviceTypeCode-selfServicehttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill point/station is self-service.

Full service

https://vocab.eona-x.eu/datex-ii/serviceTypeCode-fullServicehttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill point/station is fully serviced by staff.

Service type code

https://vocab.eona-x.eu/datex-ii/serviceTypeCodehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The native DATEX II service-type value (full service, self-service, or unattended).
Scope note
Value type: enumeration (ServiceTypeEnum) — see narrower code values. Multi-valued.

Service type

https://vocab.eona-x.eu/datex-ii/ServiceTypehttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
How a refill point or station is serviced: full service, self-service, or unattended.

Refill point status (containment)

https://vocab.eona-x.eu/datex-ii/refillPointStatushttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The status of a refill point at this station. The containment edge from StationStatus down to RefillPointStatus (and its specialisation ElectricChargingPointStatus).
Scope note
Value type: object reference (DATEX II RefillPointStatus) — see that entity and its specialisation. Multi-valued.

Is available

https://vocab.eona-x.eu/datex-ii/isAvailablehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Whether the station as a whole is currently available.
Scope note
Value type: xsd:boolean. DATEX II native type: Boolean.

Energy infrastructure station status

https://vocab.eona-x.eu/datex-ii/EnergyInfrastructureStationStatushttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The dynamic operational status of an energy infrastructure station (overall availability and the status of its refill points). The status counterpart of EnergyInfrastructureStation.

Energy infrastructure station status (containment)

https://vocab.eona-x.eu/datex-ii/energyInfrastructureStationStatushttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The status of a station at this site. The containment edge from SiteStatus down to StationStatus.
Scope note
Value type: object reference (DATEX II EnergyInfrastructureStationStatus) — see that entity. Multi-valued.

Available truck parking places

https://vocab.eona-x.eu/datex-ii/availableTruckParkingPlaceshttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The number of truck parking places currently available at the site.
Scope note
Value type: xsd:nonNegativeInteger. DATEX II native type: NonNegativeInteger.

Available car parking places

https://vocab.eona-x.eu/datex-ii/availableCarParkingPlaceshttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The number of car parking places currently available at the site.
Scope note
Value type: xsd:nonNegativeInteger. DATEX II native type: NonNegativeInteger.

Energy infrastructure site status

https://vocab.eona-x.eu/datex-ii/EnergyInfrastructureSiteStatushttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The dynamic operational status of an energy infrastructure site (available parking places, and the status of its stations). The status counterpart of EnergyInfrastructureSite.

Electric energy mix override

https://vocab.eona-x.eu/datex-ii/electricEnergyMixOverridehttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A real-time override of the charging point's normal electric energy mix (e.g. reflecting the current grid mix rather than the static/contractual one).
Scope note
Value type: object reference (DATEX II ElectricEnergyMix) — see the ElectricEnergyMix entity. Multi-valued.

Next available charging slots

https://vocab.eona-x.eu/datex-ii/nextAvailableChargingSlotshttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The date/time(s) at which the charging point is next expected to become available.
Scope note
Value type: xsd:dateTime. DATEX II native type: DateTime. Multi-valued.

Current charging power

https://vocab.eona-x.eu/datex-ii/currentChargingPowerhttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The power currently being delivered at the charging point.
Scope note
Value type: xsd:decimal (kW). DATEX II native type: Watt (float).

Current voltage

https://vocab.eona-x.eu/datex-ii/currentVoltagehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The voltage currently being delivered at the charging point.
Scope note
Value type: xsd:decimal (V). DATEX II native type: Volt (float).

Remaining charging time

https://vocab.eona-x.eu/datex-ii/remainingChargingTimehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The estimated remaining time of the current charging session.
Scope note
Value type: xsd:decimal (seconds). DATEX II native type: Seconds (float).

Electric charging point status

https://vocab.eona-x.eu/datex-ii/ElectricChargingPointStatushttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The dynamic operational status of an electric vehicle charging point (remaining charging time, current voltage/power, next available slots). The status counterpart of ElectricVehicleChargingPoint, specialising RefillPointStatus.

Waiting time

https://vocab.eona-x.eu/datex-ii/waitingTimehttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The estimated waiting time to use the refill point.
Scope note
Value type: object reference (DATEX II Facilities DurationValue; external, out of scope).

Units in stock

https://vocab.eona-x.eu/datex-ii/unitsInStockhttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The number of delivery units currently in stock at the refill point, in the unit given by the owning RefillPoint's datex:deliveryUnit.
Scope note
Value type: xsd:decimal. DATEX II native type: Units (float).

Unknown

https://vocab.eona-x.eu/datex-ii/refillPointStatusCode-unknownhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill point's status is unknown.

Unavailable

https://vocab.eona-x.eu/datex-ii/refillPointStatusCode-unavailablehttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill point is unavailable.

Reserved

https://vocab.eona-x.eu/datex-ii/refillPointStatusCode-reservedhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill point is reserved.

Removed

https://vocab.eona-x.eu/datex-ii/refillPointStatusCode-removedhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill point has been removed.

Planned

https://vocab.eona-x.eu/datex-ii/refillPointStatusCode-plannedhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill point is planned but not yet in service.

Out of stock

https://vocab.eona-x.eu/datex-ii/refillPointStatusCode-outOfStockhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill point has no fuel/energy in stock.

Out of order

https://vocab.eona-x.eu/datex-ii/refillPointStatusCode-outOfOrderhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill point is out of order.

Occupied

https://vocab.eona-x.eu/datex-ii/refillPointStatusCode-occupiedhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill point is occupied by a vehicle.

Inoperative

https://vocab.eona-x.eu/datex-ii/refillPointStatusCode-inoperativehttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill point is not operative.

Faulted

https://vocab.eona-x.eu/datex-ii/refillPointStatusCode-faultedhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill point has a fault.

Charging

https://vocab.eona-x.eu/datex-ii/refillPointStatusCode-charginghttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill point is currently delivering energy.

Blocked

https://vocab.eona-x.eu/datex-ii/refillPointStatusCode-blockedhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill point is blocked (physically or administratively).

Available

https://vocab.eona-x.eu/datex-ii/refillPointStatusCode-availablehttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill point is operational and free to use.

Refill point status code

https://vocab.eona-x.eu/datex-ii/refillPointStatusCodehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The native DATEX II operational status of the refill point (e.g. available, occupied, faulted, out of order).
Scope note
Value type: enumeration (RefillPointStatusEnum) — see narrower code values. Required in DATEX II.

Refill point status

https://vocab.eona-x.eu/datex-ii/RefillPointStatushttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The dynamic operational status of a refill point (availability, stock level, waiting time). The status counterpart of RefillPoint.

Renewable sources ratio

https://vocab.eona-x.eu/datex-ii/renewableSourcesRatiohttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The percentage of the dispensed hydrogen produced from renewable sources.
Scope note
Value type: xsd:decimal (percentage). DATEX II native type: Percentage (float).

Unknown fuelling protocol

https://vocab.eona-x.eu/datex-ii/processProtocol-unknownhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The fuelling process protocol is unknown.

MC method

https://vocab.eona-x.eu/datex-ii/processProtocol-mcMethodhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Hydrogen fuelling using the MC (Mass Consumption / Manufacturer's Chart) method.

SAE J2601:2016

https://vocab.eona-x.eu/datex-ii/processProtocol-sae2601v2016http://www.w3.org/2004/02/skos/core#Concept

Definition
Hydrogen fuelling per SAE J2601, 2016 revision.

SAE J2601:2014

https://vocab.eona-x.eu/datex-ii/processProtocol-sae2601v2014http://www.w3.org/2004/02/skos/core#Concept

Definition
Hydrogen fuelling per SAE J2601, 2014 revision.

SAE J2601:2010

https://vocab.eona-x.eu/datex-ii/processProtocol-sae2601v2010http://www.w3.org/2004/02/skos/core#Concept

Definition
Hydrogen fuelling per SAE J2601, 2010 revision.

Fuelling process protocol

https://vocab.eona-x.eu/datex-ii/processProtocolhttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The hydrogen fuelling process protocol used (e.g. an SAE J2601 revision).
Scope note
Value type: enumeration (HydrogenFuellingProcessProtocolEnum) — see narrower code values.

Unknown refill solution

https://vocab.eona-x.eu/datex-ii/refillSolution-unknownhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The refill solution is unknown.

Cryo-compressed hydrogen

https://vocab.eona-x.eu/datex-ii/refillSolution-cryoCompressedHydrogrenhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Cryo-compressed hydrogen. (Native DATEX II enumeration literal is misspelled 'cryoCompressedHydrogren'; preserved verbatim in skos:notation for fidelity.)

Liquid hydrogen

https://vocab.eona-x.eu/datex-ii/refillSolution-liquidHydrogenhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Liquid hydrogen.

Gaseous hydrogen 700 bar (truck)

https://vocab.eona-x.eu/datex-ii/refillSolution-gaseousHydrogen700barTruckhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Gaseous hydrogen at 700 bar, for trucks.

Gaseous hydrogen 700 bar (car)

https://vocab.eona-x.eu/datex-ii/refillSolution-gaseousHydrogen700barCarhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Gaseous hydrogen at 700 bar, for cars.

Gaseous hydrogen 350 bar (truck)

https://vocab.eona-x.eu/datex-ii/refillSolution-gaseousHydrogen350barTruckhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Gaseous hydrogen at 350 bar, for trucks.

Gaseous hydrogen 350 bar (car)

https://vocab.eona-x.eu/datex-ii/refillSolution-gaseousHydrogen350barCarhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Gaseous hydrogen at 350 bar, for cars.

Refill solution

https://vocab.eona-x.eu/datex-ii/refillSolutionhttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The hydrogen refuelling solution offered (pressure/temperature/vehicle-class combination, e.g. gaseous hydrogen at 700 bar for cars).
Scope note
Value type: enumeration (RefillSolutionHydrogenEnum) — see narrower code values. Required in DATEX II.

Hydrogen refill point

https://vocab.eona-x.eu/datex-ii/HydrogenRefillPointhttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A refill point specialised for dispensing hydrogen fuel.

Unknown organic gas type

https://vocab.eona-x.eu/datex-ii/organicGasType-unknownhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The organic gas type is unknown.

Other organic gas type

https://vocab.eona-x.eu/datex-ii/organicGasType-otherhttp://www.w3.org/2004/02/skos/core#Concept

Definition
An organic gas type not covered by the enumerated values.

Biogas

https://vocab.eona-x.eu/datex-ii/organicGasType-biogashttp://www.w3.org/2004/02/skos/core#Concept

Definition
Biogas.

LPG

https://vocab.eona-x.eu/datex-ii/organicGasType-lpghttp://www.w3.org/2004/02/skos/core#Concept

Definition
Liquefied Petroleum Gas.

LNG

https://vocab.eona-x.eu/datex-ii/organicGasType-lnghttp://www.w3.org/2004/02/skos/core#Concept

Definition
Liquefied Natural Gas.

CNG

https://vocab.eona-x.eu/datex-ii/organicGasType-cnghttp://www.w3.org/2004/02/skos/core#Concept

Definition
Compressed Natural Gas.

All organic gas types

https://vocab.eona-x.eu/datex-ii/organicGasType-allhttp://www.w3.org/2004/02/skos/core#Concept

Definition
All organic gas types are dispensed.

Organic gas type

https://vocab.eona-x.eu/datex-ii/organicGasTypehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The type(s) of organic gas fuel dispensed (e.g. CNG, LNG, LPG, biogas).
Scope note
Value type: enumeration (OrganicGasTypeEnum) — see narrower code values. Multi-valued.

Organic gas refill point

https://vocab.eona-x.eu/datex-ii/OrganicGasRefillPointhttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A refill point specialised for dispensing organic/natural gas fuel (CNG, LNG, LPG, biogas).

Other bioethanol type

https://vocab.eona-x.eu/datex-ii/bioethanolType-otherhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A bioethanol type not covered by the enumerated values.

Unknown bioethanol type

https://vocab.eona-x.eu/datex-ii/bioethanolType-unknownhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The bioethanol type is unknown.

Super E10

https://vocab.eona-x.eu/datex-ii/bioethanolType-superE10http://www.w3.org/2004/02/skos/core#Concept

Definition
Bioethanol blend with up to 10% ethanol content.

Super E5

https://vocab.eona-x.eu/datex-ii/bioethanolType-superE5http://www.w3.org/2004/02/skos/core#Concept

Definition
Bioethanol blend with up to 5% ethanol content.

Bioethanol type

https://vocab.eona-x.eu/datex-ii/bioethanolTypehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The type of bioethanol blend dispensed (e.g. Super E5, Super E10).
Scope note
Value type: enumeration (BioethanolTypeEnum) — see narrower code values.

Bioethanol percentage

https://vocab.eona-x.eu/datex-ii/bioethanolPercentagehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The percentage of bioethanol in the petrol fuel dispensed.
Scope note
Value type: xsd:decimal (percentage). DATEX II native type: Percentage (float).

Octane number

https://vocab.eona-x.eu/datex-ii/octanehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The octane number of the petrol fuel dispensed.
Scope note
Value type: xsd:nonNegativeInteger. DATEX II native type: NonNegativeInteger.

Unknown petrol type

https://vocab.eona-x.eu/datex-ii/petrolType-unknownhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The petrol type is unknown.

Other petrol type

https://vocab.eona-x.eu/datex-ii/petrolType-otherhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A petrol type not covered by the enumerated values.

Super E10

https://vocab.eona-x.eu/datex-ii/petrolType-superE10http://www.w3.org/2004/02/skos/core#Concept

Definition
Petrol with up to 10% ethanol content.

Super E5

https://vocab.eona-x.eu/datex-ii/petrolType-superE5http://www.w3.org/2004/02/skos/core#Concept

Definition
Petrol with up to 5% ethanol content.

Unleaded

https://vocab.eona-x.eu/datex-ii/petrolType-unleadedhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Unleaded petrol.

Leaded

https://vocab.eona-x.eu/datex-ii/petrolType-leadedhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Leaded petrol.

Octane 98

https://vocab.eona-x.eu/datex-ii/petrolType-octane98http://www.w3.org/2004/02/skos/core#Concept

Definition
Petrol with an octane rating of 98.

Octane 95

https://vocab.eona-x.eu/datex-ii/petrolType-octane95http://www.w3.org/2004/02/skos/core#Concept

Definition
Petrol with an octane rating of 95.

All petrol types

https://vocab.eona-x.eu/datex-ii/petrolType-allhttp://www.w3.org/2004/02/skos/core#Concept

Definition
All petrol types are dispensed.

Petrol type

https://vocab.eona-x.eu/datex-ii/petrolTypehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The type(s) of petrol fuel dispensed (e.g. octane 95, octane 98, unleaded).
Scope note
Value type: enumeration (PetrolTypeEnum) — see narrower code values. Multi-valued.

Petrol refill point

https://vocab.eona-x.eu/datex-ii/PetrolRefillPointhttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A refill point specialised for dispensing petrol (gasoline) fuel.

Cetane number

https://vocab.eona-x.eu/datex-ii/cetanehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The cetane number of the diesel fuel dispensed.
Scope note
Value type: xsd:nonNegativeInteger. DATEX II native type: NonNegativeInteger.

Unknown diesel type

https://vocab.eona-x.eu/datex-ii/dieselType-unknownhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The diesel type is unknown.

Biodiesel

https://vocab.eona-x.eu/datex-ii/dieselType-bioDieselhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Biodiesel fuel.

Truck diesel

https://vocab.eona-x.eu/datex-ii/dieselType-truckDieselhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Diesel fuel for trucks.

Car diesel

https://vocab.eona-x.eu/datex-ii/dieselType-carDieselhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Diesel fuel for passenger cars.

Diesel type

https://vocab.eona-x.eu/datex-ii/dieselTypehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The type(s) of diesel fuel dispensed (e.g. car diesel, truck diesel, biodiesel).
Scope note
Value type: enumeration (DieselTypeEnum) — see narrower code values. Multi-valued.

Diesel refill point

https://vocab.eona-x.eu/datex-ii/DieselRefillPointhttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A refill point specialised for dispensing diesel fuel.

Service type

https://vocab.eona-x.eu/datex-ii/serviceTypehttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The way the refill point is serviced (full service, self-service, or unattended).
Scope note
Value type: object reference (DATEX II ServiceType) — see the ServiceType entity.

Reservation

https://vocab.eona-x.eu/datex-ii/reservationhttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Whether the refill point can be reserved in advance. External enumeration (DATEX II Facilities ReservationTypeEnum: optional, mandatory, notAvailable, partly, unknown, unspecified) — code values are not modelled in this hub-curated subset (out of scope, Facilities namespace).
Scope note
Value type: enumeration (DATEX II Facilities ReservationTypeEnum; external, out of scope — code values not modelled).

Model type

https://vocab.eona-x.eu/datex-ii/modelTypehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The manufacturer's model designation of the refill point.
Scope note
Value type: xsd:string. DATEX II native type: MultilingualString.

Minimum delivery amount

https://vocab.eona-x.eu/datex-ii/minimumDeliveryAmounthttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The minimum amount of energy/fuel that can be delivered in a single session, in the unit given by datex:deliveryUnit.
Scope note
Value type: xsd:decimal. DATEX II native type: Units (float).

Maximum delivery amount

https://vocab.eona-x.eu/datex-ii/maximumDeliveryAmounthttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The maximum amount of energy/fuel that can be delivered in a single session, in the unit given by datex:deliveryUnit.
Scope note
Value type: xsd:decimal. DATEX II native type: Units (float).

Gas gallon equivalent

https://vocab.eona-x.eu/datex-ii/deliveryUnit-gasGallonEquivalenthttp://www.w3.org/2004/02/skos/core#Concept

Definition
Delivery measured in gas gallon equivalent (GGE).

US gallon

https://vocab.eona-x.eu/datex-ii/deliveryUnit-usGallonhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Delivery measured in US gallons.

Imperial gallon

https://vocab.eona-x.eu/datex-ii/deliveryUnit-imperialGallonhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Delivery measured in imperial gallons.

Cubic metre

https://vocab.eona-x.eu/datex-ii/deliveryUnit-m3http://www.w3.org/2004/02/skos/core#Concept

Definition
Delivery measured in cubic metres.

Kilogram

https://vocab.eona-x.eu/datex-ii/deliveryUnit-kghttp://www.w3.org/2004/02/skos/core#Concept

Definition
Delivery measured in kilograms.

Kilowatt-hour

https://vocab.eona-x.eu/datex-ii/deliveryUnit-kWhhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Delivery measured in kilowatt-hours.

Litre

https://vocab.eona-x.eu/datex-ii/deliveryUnit-litrehttp://www.w3.org/2004/02/skos/core#Concept

Definition
Delivery measured in litres.

Delivery unit

https://vocab.eona-x.eu/datex-ii/deliveryUnithttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The unit in which energy/fuel is delivered at the refill point (e.g. litre, kWh, kg).
Scope note
Value type: enumeration (DeliveryUnitEnum) — see narrower code values.

Refill point (abstract)

https://vocab.eona-x.eu/datex-ii/RefillPointhttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Technical infrastructure at a specific location that facilitates refilling one vehicle at a time with any form of energy (electricity, diesel, petrol, organic gas, hydrogen). Abstract superclass of ElectricVehicleChargingPoint (already modelled above) and of DieselRefillPoint, PetrolRefillPoint, OrganicGasRefillPoint and HydrogenRefillPoint (modelled below).

DATEX II — EnergyInfrastructure (EV-charging subset)

https://vocab.eona-x.eu/datex-ii/energy-infrastructurehttp://www.w3.org/2004/02/skos/core#ConceptScheme

Description
EV-charging (IRVE) terms curated from the DATEX II EnergyInfrastructure model for the EMDS demo. Entities, their attributes, attribute value types and enumeration code values.

Domestic socket type O

https://vocab.eona-x.eu/datex-ii/connectorType-domesticOhttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC/CEE domestic socket type O, a regional household-socket variant of datex:connectorType-domestic.

Domestic socket type N

https://vocab.eona-x.eu/datex-ii/connectorType-domesticNhttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC/CEE domestic socket type N, a regional household-socket variant of datex:connectorType-domestic.

Domestic socket type M

https://vocab.eona-x.eu/datex-ii/connectorType-domesticMhttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC/CEE domestic socket type M, a regional household-socket variant of datex:connectorType-domestic.

Domestic socket type L

https://vocab.eona-x.eu/datex-ii/connectorType-domesticLhttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC/CEE domestic socket type L, a regional household-socket variant of datex:connectorType-domestic.

Domestic socket type K

https://vocab.eona-x.eu/datex-ii/connectorType-domesticKhttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC/CEE domestic socket type K, a regional household-socket variant of datex:connectorType-domestic.

Domestic socket type J

https://vocab.eona-x.eu/datex-ii/connectorType-domesticJhttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC/CEE domestic socket type J, a regional household-socket variant of datex:connectorType-domestic.

Domestic socket type I

https://vocab.eona-x.eu/datex-ii/connectorType-domesticIhttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC/CEE domestic socket type I, a regional household-socket variant of datex:connectorType-domestic.

Domestic socket type H

https://vocab.eona-x.eu/datex-ii/connectorType-domesticHhttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC/CEE domestic socket type H, a regional household-socket variant of datex:connectorType-domestic.

Domestic socket type G

https://vocab.eona-x.eu/datex-ii/connectorType-domesticGhttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC/CEE domestic socket type G, a regional household-socket variant of datex:connectorType-domestic.

Domestic socket type F

https://vocab.eona-x.eu/datex-ii/connectorType-domesticFhttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC/CEE domestic socket type F, a regional household-socket variant of datex:connectorType-domestic.

Domestic socket type E

https://vocab.eona-x.eu/datex-ii/connectorType-domesticEhttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC/CEE domestic socket type E, a regional household-socket variant of datex:connectorType-domestic.

Domestic socket type D

https://vocab.eona-x.eu/datex-ii/connectorType-domesticDhttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC/CEE domestic socket type D, a regional household-socket variant of datex:connectorType-domestic.

Domestic socket type C

https://vocab.eona-x.eu/datex-ii/connectorType-domesticChttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC/CEE domestic socket type C, a regional household-socket variant of datex:connectorType-domestic.

Domestic socket type B

https://vocab.eona-x.eu/datex-ii/connectorType-domesticBhttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC/CEE domestic socket type B, a regional household-socket variant of datex:connectorType-domestic.

Domestic socket type A

https://vocab.eona-x.eu/datex-ii/connectorType-domesticAhttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC/CEE domestic socket type A, a regional household-socket variant of datex:connectorType-domestic.

Connector type

https://vocab.eona-x.eu/datex-ii/connectorTypehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The type of physical connector / charging interface offered (e.g. Type 2, CCS Combo 2, CHAdeMO).
Scope note
Value type: enumeration (ConnectorTypeEnum) — see narrower code values. Required in DATEX II.

PLC

https://vocab.eona-x.eu/datex-ii/authMethod-plchttp://www.w3.org/2004/02/skos/core#Concept

Definition
Identification/authentication via Power Line Communication (ISO 15118).

PIN pad

https://vocab.eona-x.eu/datex-ii/authMethod-pinpadhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Identification/authentication via a PIN pad.

Phone SMS

https://vocab.eona-x.eu/datex-ii/authMethod-phoneSMShttp://www.w3.org/2004/02/skos/core#Concept

Definition
Identification/authentication via SMS text message.

Phone dialog

https://vocab.eona-x.eu/datex-ii/authMethod-phoneDialoghttp://www.w3.org/2004/02/skos/core#Concept

Definition
Identification/authentication via an interactive phone call.

Over the air

https://vocab.eona-x.eu/datex-ii/authMethod-overTheAirhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Identification/authentication performed over the air (remote activation).

MIFARE DESFire

https://vocab.eona-x.eu/datex-ii/authMethod-mifareDesfirehttp://www.w3.org/2004/02/skos/core#Concept

Definition
Identification via a MIFARE DESFire contactless card.

MIFARE Classic

https://vocab.eona-x.eu/datex-ii/authMethod-mifareClassichttp://www.w3.org/2004/02/skos/core#Concept

Definition
Identification via a MIFARE Classic contactless card.

Calypso

https://vocab.eona-x.eu/datex-ii/authMethod-calypsohttp://www.w3.org/2004/02/skos/core#Concept

Definition
Identification via the Calypso contactless ticketing standard.

Active RFID chip

https://vocab.eona-x.eu/datex-ii/authMethod-activeRFIDChiphttp://www.w3.org/2004/02/skos/core#Concept

Definition
Identification by an active (powered) RFID chip.

Authentication and identification methods

https://vocab.eona-x.eu/datex-ii/authenticationAndIdentificationMethodshttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The methods of identification and/or authentication accepted to start a charging session at the station.
Scope note
Value type: enumeration (AuthenticationAndIdentificationEnum) — see narrower code values.

Electric energy source ratio (containment)

https://vocab.eona-x.eu/datex-ii/electricEnergySourceRatiohttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A source/ratio pair making up this energy mix (e.g. 40% solar). The containment edge from ElectricEnergyMix down to ElectricEnergySourceRatio.
Scope note
Value type: object reference (DATEX II ElectricEnergySourceRatio) — see the ElectricEnergySourceRatio entity. Multi-valued.

Energy mix index

https://vocab.eona-x.eu/datex-ii/energyMixIndexhttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The index (ordinal) of this energy mix entry among the charging point's possible energy mixes.
Scope note
Value type: xsd:integer. DATEX II native type: Integer (XML attribute). Required in DATEX II.

Energy mix rates

https://vocab.eona-x.eu/datex-ii/energyMixRateshttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The pricing/rates applicable to this energy mix.
Scope note
Value type: object reference (DATEX II Facilities Rates; external, out of scope).

Energy mix provider

https://vocab.eona-x.eu/datex-ii/energyMixProviderhttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The organisation providing this specific energy mix.
Scope note
Value type: object reference (DATEX II Organisation; external, out of scope — same pattern as the pre-existing datex:energyProvider).

Not available

https://vocab.eona-x.eu/datex-ii/notAvailablehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Whether energy-mix information is not available for this charging point.
Scope note
Value type: xsd:boolean. DATEX II native type: Boolean.

Nuclear waste impact

https://vocab.eona-x.eu/datex-ii/nuclearWasteImpacthttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The nuclear waste impact of the energy mix.
Scope note
Value type: xsd:decimal. DATEX II native type: Float.

Carbon dioxide impact

https://vocab.eona-x.eu/datex-ii/carbonDioxideImpacthttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The carbon dioxide impact of the energy mix.
Scope note
Value type: xsd:decimal. DATEX II native type: Float.

Is green energy

https://vocab.eona-x.eu/datex-ii/isGreenEnergyhttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Whether the energy mix is marketed/certified as green (renewable) energy.
Scope note
Value type: xsd:boolean. DATEX II native type: Boolean.

Energy product name

https://vocab.eona-x.eu/datex-ii/energyProductNamehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The commercial name of the energy product (electricity tariff/mix product).
Scope note
Value type: xsd:string. DATEX II native type: MultilingualString.

Electric energy mix

https://vocab.eona-x.eu/datex-ii/ElectricEnergyMixhttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The mix of energy sources of the electricity delivered at an electric charging point, optionally with per-source ratios.

Country of domestic socket

https://vocab.eona-x.eu/datex-ii/countryOfDomesticSockethttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The country whose domestic socket standard the connector implements (relevant when datex:connectorType is a domestic socket variant).
Scope note
Value type: xsd:string. DATEX II native type: CountryCode (ISO 3166-1 alpha-2). Multi-valued.

Other connector (free text)

https://vocab.eona-x.eu/datex-ii/otherConnectorhttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Free-text description of the connector type when datex:connectorType is 'other'.
Scope note
Value type: xsd:string. DATEX II native type: String.

Connector

https://vocab.eona-x.eu/datex-ii/Connectorhttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Parameters and description of an interface available at an electric charging point to connect vehicles (the charging interface type and cable information).

Vehicle space

https://vocab.eona-x.eu/datex-ii/vehicleSpacehttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
An adjacent vehicle space (parking space) usually directly linked with the charging point.
Scope note
Value type: object reference (DATEX II VehicleSpace) — see the VehicleSpace entity. Multi-valued.

Unknown V2G communication

https://vocab.eona-x.eu/datex-ii/vehicleToGridCommunicationType-unknownhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The vehicle-to-grid communication type is unknown.

Other V2G communication

https://vocab.eona-x.eu/datex-ii/vehicleToGridCommunicationType-otherhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A vehicle-to-grid communication type not covered by the enumerated values.

IEC 61980-2

https://vocab.eona-x.eu/datex-ii/vehicleToGridCommunicationType-iec619802http://www.w3.org/2004/02/skos/core#Concept

Definition
Vehicle-to-grid communication per IEC 61980-2.

ISO 15118

https://vocab.eona-x.eu/datex-ii/vehicleToGridCommunicationType-iso15118http://www.w3.org/2004/02/skos/core#Concept

Definition
Vehicle-to-grid communication per ISO 15118.

None

https://vocab.eona-x.eu/datex-ii/vehicleToGridCommunicationType-nonehttp://www.w3.org/2004/02/skos/core#Concept

Definition
No vehicle-to-grid communication is supported.

Vehicle-to-grid communication type

https://vocab.eona-x.eu/datex-ii/vehicleToGridCommunicationTypehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The vehicle-to-grid (V2G) communication protocol supported at the charging point.
Scope note
Value type: enumeration (VehicleToGridCommunicationTypeEnum) — see narrower code values. Multi-valued.

Other usage type

https://vocab.eona-x.eu/datex-ii/usageType-otherhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A usage type not covered by the enumerated values.

Overhead-line-driven vehicles

https://vocab.eona-x.eu/datex-ii/usageType-overheadLineDrivenVehicleshttp://www.w3.org/2004/02/skos/core#Concept

Definition
Intended for overhead-line-driven vehicles (e.g. electric trucks/buses).

Motorhome or caravan supply

https://vocab.eona-x.eu/datex-ii/usageType-motorhomeOrCaravanSupplyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Intended for supplying motorhomes or caravans.

Lorry power consumption

https://vocab.eona-x.eu/datex-ii/usageType-lorryPowerConsumptionhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Intended for supplying lorry auxiliary power consumption.

Electric vehicle

https://vocab.eona-x.eu/datex-ii/usageType-electricVehiclehttp://www.w3.org/2004/02/skos/core#Concept

Definition
Intended for charging electric vehicles (cars).

Electric motorcycle

https://vocab.eona-x.eu/datex-ii/usageType-electricMotorcyclehttp://www.w3.org/2004/02/skos/core#Concept

Definition
Intended for charging electric motorcycles.

Electrical devices

https://vocab.eona-x.eu/datex-ii/usageType-electricalDeviceshttp://www.w3.org/2004/02/skos/core#Concept

Definition
Intended for charging small electrical devices.

Electric bike

https://vocab.eona-x.eu/datex-ii/usageType-electricBikehttp://www.w3.org/2004/02/skos/core#Concept

Definition
Intended for charging electric bikes.

Electric boat

https://vocab.eona-x.eu/datex-ii/usageType-electricBoathttp://www.w3.org/2004/02/skos/core#Concept

Definition
Intended for charging electric boats.

Usage type

https://vocab.eona-x.eu/datex-ii/usageTypehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The kind of vehicle/device the charging point is intended for (e.g. electric vehicle, electric bike, electric boat).
Scope note
Value type: enumeration (ChargingPointUsageTypeEnum) — see narrower code values. Multi-valued.

Electric Vehicle Charging Point

https://vocab.eona-x.eu/datex-ii/ElectricVehicleChargingPointhttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Technical infrastructure at a specific location that facilitates electric charging of one vehicle at a time. A specialisation of the abstract RefillPoint.

Refill point (containment)

https://vocab.eona-x.eu/datex-ii/refillPointhttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A refill point of this station, embedded inline. The containment edge from Station down to RefillPoint (and its specialisations, e.g. ElectricVehicleChargingPoint).
Scope note
Value type: object reference (DATEX II RefillPoint) — see the RefillPoint entity and its specialisations. Multi-valued.

Station service type

https://vocab.eona-x.eu/datex-ii/stationServiceTypehttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The way the station's refill points are serviced (full service, self-service, or unattended).
Scope note
Value type: object reference (DATEX II ServiceType) — see the ServiceType entity.

Energy distributor

https://vocab.eona-x.eu/datex-ii/energyDistributorhttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The organisation distributing the energy at the station (as distinct from the energy provider/producer).
Scope note
Value type: object reference (DATEX II Organisation; external, out of scope — same pattern as the pre-existing datex:energyProvider).

User interface language

https://vocab.eona-x.eu/datex-ii/userInterfaceLanguagehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A language supported by the station's user interface / payment terminal.
Scope note
Value type: xsd:language. DATEX II native type: Language (ISO 639-1 code). Multi-valued.

Refill point (by reference)

https://vocab.eona-x.eu/datex-ii/refillPointByReferencehttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A refill point of this station, referenced by identifier rather than embedded inline (e.g. one already published separately).
Scope note
Value type: object reference (DATEX II VersionedReference targeting a RefillPoint) — see the RefillPoint entity. Multi-valued.

Number of refill points

https://vocab.eona-x.eu/datex-ii/numberOfRefillPointshttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The number of refill points (e.g. charging points) available at the station.
Scope note
Value type: xsd:nonNegativeInteger. DATEX II native type: NonNegativeInteger.

Energy infrastructure station

https://vocab.eona-x.eu/datex-ii/EnergyInfrastructureStationhttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A collection of associated refill points on a site (for EV charging, a charging station grouping one or more charging points). Often the vehicle space is shared between its refill points.

Energy infrastructure station (containment)

https://vocab.eona-x.eu/datex-ii/energyInfrastructureStationhttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The energy infrastructure station(s) located on this site. The containment edge from Site down to Station.
Scope note
Value type: object reference (DATEX II EnergyInfrastructureStation) — see the EnergyInfrastructureStation entity. Multi-valued.

Exit

https://vocab.eona-x.eu/datex-ii/exithttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The geographic location of an exit from the site.
Scope note
Value type: object reference (DATEX II Location; external, out of scope — see the pre-existing datex:entrance for the same pattern). Multi-valued.

Preferred users

https://vocab.eona-x.eu/datex-ii/preferredUsershttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The user group(s) for whom this site is preferentially intended (non-exclusive). External enumeration (DATEX II Facilities UserTypeEnum) — code values are not modelled in this hub-curated subset (out of scope, Facilities namespace).
Scope note
Value type: enumeration (DATEX II Facilities UserTypeEnum; external, out of scope — code values not modelled). Multi-valued.

Exclusive users

https://vocab.eona-x.eu/datex-ii/exclusiveUsershttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The user group(s) exclusively allowed to use this site (e.g. employees, hotel guests). External enumeration (DATEX II Facilities UserTypeEnum) — code values are not modelled in this hub-curated subset (out of scope, Facilities namespace).
Scope note
Value type: enumeration (DATEX II Facilities UserTypeEnum; external, out of scope — code values not modelled). Multi-valued.

Other site type

https://vocab.eona-x.eu/datex-ii/typeOfSite-otherhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A site type not covered by the enumerated values.

On company site

https://vocab.eona-x.eu/datex-ii/typeOfSite-onCompanySitehttp://www.w3.org/2004/02/skos/core#Concept

Definition
The site is located on a company's premises.

On-street

https://vocab.eona-x.eu/datex-ii/typeOfSite-onstreethttp://www.w3.org/2004/02/skos/core#Concept

Definition
The site is located on-street.

Open space

https://vocab.eona-x.eu/datex-ii/typeOfSite-openSpacehttp://www.w3.org/2004/02/skos/core#Concept

Definition
The site is an open, unroofed space.

In building

https://vocab.eona-x.eu/datex-ii/typeOfSite-inBuildinghttp://www.w3.org/2004/02/skos/core#Concept

Definition
The site is located inside a building.

Roofed station

https://vocab.eona-x.eu/datex-ii/typeOfSite-roofedStationhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The site is a roofed station.

Type of site

https://vocab.eona-x.eu/datex-ii/typeOfSitehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The physical type of the energy infrastructure site (e.g. roofed station, in a building, open space, on-street, on a company site).
Scope note
Value type: enumeration (EnergyInfrastructureSiteTypeEnum) — see narrower code values.

Energy infrastructure site

https://vocab.eona-x.eu/datex-ii/EnergyInfrastructureSitehttp://www.w3.org/2002/07/owl#Classhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A site where vehicles can be supplied with energy, including all buildings, stations, parking spaces and associated services. Contains one or more energy infrastructure stations.

Energy source ratio (%)

https://vocab.eona-x.eu/datex-ii/energySourceRatiohttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The percentage share of a given energy source within the electric energy mix.
Scope note
Value type: xsd:decimal (percentage). DATEX II native type: Percentage (float).

Other energy source

https://vocab.eona-x.eu/datex-ii/energySourceType-otherhttp://www.w3.org/2004/02/skos/core#Concept

Definition
An energy source not covered by the enumerated values.

General fossil

https://vocab.eona-x.eu/datex-ii/energySourceType-generalFossilhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Electricity from a general fossil mix.

General green

https://vocab.eona-x.eu/datex-ii/energySourceType-generalGreenhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Electricity from a general green / renewable mix.

Gas

https://vocab.eona-x.eu/datex-ii/energySourceType-gashttp://www.w3.org/2004/02/skos/core#Concept

Definition
Electricity from gas.

Coal

https://vocab.eona-x.eu/datex-ii/energySourceType-coalhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Electricity from coal.

Nuclear

https://vocab.eona-x.eu/datex-ii/energySourceType-nuclearhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Electricity from nuclear sources.

Biogas

https://vocab.eona-x.eu/datex-ii/energySourceType-biogashttp://www.w3.org/2004/02/skos/core#Concept

Definition
Electricity from biogas.

Water

https://vocab.eona-x.eu/datex-ii/energySourceType-waterhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Electricity from hydro / water sources.

Wind

https://vocab.eona-x.eu/datex-ii/energySourceType-windhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Electricity from wind sources.

Solar

https://vocab.eona-x.eu/datex-ii/energySourceType-solarhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Electricity from solar sources.

Energy source type

https://vocab.eona-x.eu/datex-ii/energySourceTypehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The type of energy source in the electric energy mix.
Scope note
Value type: enumeration (ElectricEnergySourceTypeEnum) — see narrower code values.

Maximum current (A)

https://vocab.eona-x.eu/datex-ii/maximumCurrenthttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The maximum current available at the connector.
Scope note
Value type: xsd:decimal (A). DATEX II native type: Ampere (float).

Voltage (V)

https://vocab.eona-x.eu/datex-ii/voltagehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The voltage available at the connector.
Scope note
Value type: xsd:decimal (V). DATEX II native type: Volt (float).

Maximum power at socket (kW)

https://vocab.eona-x.eu/datex-ii/maxPowerAtSockethttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The maximum power available at the connector/socket. Required in DATEX II.
Scope note
Value type: xsd:decimal (kW). DATEX II native type: Watt (float).

Other captive cable

https://vocab.eona-x.eu/datex-ii/connectorFormat-otherCablehttp://www.w3.org/2004/02/skos/core#Concept

Definition
A permanently attached cable of another type.

Captive cable (Mode 3)

https://vocab.eona-x.eu/datex-ii/connectorFormat-cableMode3http://www.w3.org/2004/02/skos/core#Concept

Definition
A permanently attached cable for Mode 3 charging.

Captive cable (Mode 2)

https://vocab.eona-x.eu/datex-ii/connectorFormat-cableMode2http://www.w3.org/2004/02/skos/core#Concept

Definition
A permanently attached cable with Mode 2 in-cable control.

Socket

https://vocab.eona-x.eu/datex-ii/connectorFormat-sockethttp://www.w3.org/2004/02/skos/core#Concept

Definition
A socket; the driver supplies their own cable.

Connector format

https://vocab.eona-x.eu/datex-ii/connectorFormathttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Whether the connector is offered as a captive cable or as a socket, including the cable type.
Scope note
Value type: enumeration (ConnectorFormatTypeEnum) — see narrower code values.

Unknown charging mode

https://vocab.eona-x.eu/datex-ii/chargingMode-unknownhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The charging mode is unknown.

Other charging mode

https://vocab.eona-x.eu/datex-ii/chargingMode-otherhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A charging mode not covered by the enumerated values.

CCS combined charging

https://vocab.eona-x.eu/datex-ii/chargingMode-ccshttp://www.w3.org/2004/02/skos/core#Concept

Definition
Combined Charging System mode.

Legacy inductive

https://vocab.eona-x.eu/datex-ii/chargingMode-legacyInductivehttp://www.w3.org/2004/02/skos/core#Concept

Definition
Legacy inductive (wireless) charging.

Mode 4 — DC

https://vocab.eona-x.eu/datex-ii/chargingMode-mode4DChttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC 61851-1 Mode 4 charging: DC fast charging with an off-board charger.

Mode 3 — AC three-phase

https://vocab.eona-x.eu/datex-ii/chargingMode-mode3AC3phttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC 61851-1 Mode 3 charging, AC three-phase via a dedicated EVSE (the common public AC mode).

Mode 2 — AC three-phase

https://vocab.eona-x.eu/datex-ii/chargingMode-mode2AC3phttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC 61851-1 Mode 2 charging, AC three-phase.

Mode 2 — AC single-phase

https://vocab.eona-x.eu/datex-ii/chargingMode-mode2AC1phttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC 61851-1 Mode 2 charging, AC single-phase (in-cable control and protection device).

Mode 1 — AC three-phase

https://vocab.eona-x.eu/datex-ii/chargingMode-mode1AC3phttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC 61851-1 Mode 1 charging, AC three-phase.

Mode 1 — AC single-phase

https://vocab.eona-x.eu/datex-ii/chargingMode-mode1AC1phttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC 61851-1 Mode 1 charging, AC single-phase (no in-cable control).

Charging mode

https://vocab.eona-x.eu/datex-ii/chargingModehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The charging mode supported at the connector, per IEC 61851-1.
Scope note
Value type: enumeration (ChargingModeEnum) — see narrower code values.

Other connector type

https://vocab.eona-x.eu/datex-ii/connectorType-otherhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A connector type not covered by the enumerated values.

Tesla Model S connector

https://vocab.eona-x.eu/datex-ii/connectorType-teslaShttp://www.w3.org/2004/02/skos/core#Concept

Definition
Tesla Model S charging connector.

Tesla Roadster connector

https://vocab.eona-x.eu/datex-ii/connectorType-teslaRhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Tesla Roadster charging connector.

Tesla connector (America)

https://vocab.eona-x.eu/datex-ii/connectorType-teslaConnectorAmericahttp://www.w3.org/2004/02/skos/core#Concept

Definition
Tesla proprietary connector, North American variant.

Tesla connector (Europe)

https://vocab.eona-x.eu/datex-ii/connectorType-teslaConnectorEuropehttp://www.w3.org/2004/02/skos/core#Concept

Definition
Tesla proprietary connector, European variant.

Pantograph (top-down)

https://vocab.eona-x.eu/datex-ii/connectorType-pantographTopDownhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Top-down pantograph charging interface (e.g. for electric buses).

Pantograph (bottom-up)

https://vocab.eona-x.eu/datex-ii/connectorType-pantographBottomUphttp://www.w3.org/2004/02/skos/core#Concept

Definition
Bottom-up pantograph charging interface (e.g. for electric buses).

IEC 60309 three-phase 64 A

https://vocab.eona-x.eu/datex-ii/connectorType-iec60309x2three64http://www.w3.org/2004/02/skos/core#Concept

Definition
IEC 60309 industrial connector, three phase, 64 A.

IEC 60309 three-phase 32 A

https://vocab.eona-x.eu/datex-ii/connectorType-iec60309x2three32http://www.w3.org/2004/02/skos/core#Concept

Definition
IEC 60309 industrial connector, three phase, 32 A.

IEC 60309 three-phase 16 A

https://vocab.eona-x.eu/datex-ii/connectorType-iec60309x2three16http://www.w3.org/2004/02/skos/core#Concept

Definition
IEC 60309 industrial connector, three phase, 16 A.

IEC 60309 single-phase 16 A

https://vocab.eona-x.eu/datex-ii/connectorType-iec60309x2single16http://www.w3.org/2004/02/skos/core#Concept

Definition
IEC 60309 industrial connector, single phase, 16 A.

CEE 5-pin (three phase)

https://vocab.eona-x.eu/datex-ii/connectorType-cee5http://www.w3.org/2004/02/skos/core#Concept

Definition
CEE 5-pin three-phase industrial socket (red).

CEE 3-pin (single phase)

https://vocab.eona-x.eu/datex-ii/connectorType-cee3http://www.w3.org/2004/02/skos/core#Concept

Definition
CEE 3-pin single-phase industrial socket (blue).

Domestic socket

https://vocab.eona-x.eu/datex-ii/connectorType-domestichttp://www.w3.org/2004/02/skos/core#Concept

Definition
A standard household / domestic socket. (DATEX II also defines regional variants domesticA–domesticO, omitted here for brevity.)

Yazaki (SAE J1772)

https://vocab.eona-x.eu/datex-ii/connectorType-yazakihttp://www.w3.org/2004/02/skos/core#Concept

Definition
Yazaki connector (the original SAE J1772 Type 1 AC design).

CHAdeMO

https://vocab.eona-x.eu/datex-ii/connectorType-chademohttp://www.w3.org/2004/02/skos/core#Concept

Definition
CHAdeMO DC fast-charging connector (Japanese standard, bidirectional V2G/V2H capable).

Type 3C / Scame (IEC 62196-2, AC)

https://vocab.eona-x.eu/datex-ii/connectorType-iec62196T3Chttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC 62196 Type 3C AC connector (Scame).

Type 3A (IEC 62196-2, AC)

https://vocab.eona-x.eu/datex-ii/connectorType-iec62196T3Ahttp://www.w3.org/2004/02/skos/core#Concept

Definition
IEC 62196 Type 3A AC connector for light electric vehicles.

CCS Combo 1 (IEC 62196-3, DC)

https://vocab.eona-x.eu/datex-ii/connectorType-iec62196T1COMBOhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Combined Charging System Combo 1: Type 1 supplemented with two DC pins (North American DC fast charging).

Type 1 (IEC 62196-2 / SAE J1772, AC)

https://vocab.eona-x.eu/datex-ii/connectorType-iec62196T1http://www.w3.org/2004/02/skos/core#Concept

Definition
IEC 62196 Type 1 single-phase AC connector (SAE J1772 / Yazaki).

CCS Combo 2 (IEC 62196-3, DC)

https://vocab.eona-x.eu/datex-ii/connectorType-iec62196T2COMBOhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Combined Charging System Combo 2: Type 2 supplemented with two DC pins for DC fast charging.

Type 2 / Mennekes (IEC 62196-2, AC)

https://vocab.eona-x.eu/datex-ii/connectorType-iec62196T2http://www.w3.org/2004/02/skos/core#Concept

Definition
IEC 62196 Type 2 AC connector (Mennekes), the European AC charging standard.

Location (latitude/longitude)

https://vocab.eona-x.eu/datex-ii/locationhttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The geographic location of the charging point, expressed as latitude and longitude coordinates.
Scope note
Value type: object reference (DATEX II Location); coordinates expressed as xsd:decimal degrees (latitude/longitude). Inherited from Facility.

Electric energy mix

https://vocab.eona-x.eu/datex-ii/electricEnergyMixhttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The mix of energy sources of the electricity delivered at the charging point.
Scope note
Value type: object reference (DATEX II ElectricEnergyMix) — see the Electric energy mix entity.

Connector (charging interface)

https://vocab.eona-x.eu/datex-ii/connectorhttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A physical charging interface available at the charging point. A charging point may expose several connectors.
Scope note
Value type: object reference (DATEX II Connector) — see the Connector entity. Multi-valued.

Available voltage (V)

https://vocab.eona-x.eu/datex-ii/availableVoltagehttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A possible degree of voltage offered by the charging point. May be multi-valued.
Scope note
Value type: xsd:decimal (V). DATEX II native type: Volt (float), multi-valued.

Available charging power (kW)

https://vocab.eona-x.eu/datex-ii/availableChargingPowerhttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
A possible degree of charging power offered by the charging point. May be multi-valued (a charging point can support several power levels).
Scope note
Value type: xsd:decimal (kW). DATEX II native type: Watt (float), multi-valued.

Rated power (kW)

https://vocab.eona-x.eu/datex-ii/powerhttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The rated electrical power of the charging point, expressed in kilowatts.
Scope note
Value type: xsd:decimal (kW). DATEX II native type: Watt (float), e.g. ElectricChargingPoint.availableChargingPower / Connector.maxPowerAtSocket.

Unknown

https://vocab.eona-x.eu/datex-ii/status-unknownhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The operational status of the charging point is unknown.

Out of service

https://vocab.eona-x.eu/datex-ii/status-outOfServicehttp://www.w3.org/2004/02/skos/core#Concept

Definition
The charging point is not operational (technical defect or maintenance).

Reserved

https://vocab.eona-x.eu/datex-ii/status-reservedhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The charging point is reserved and not available for general use.

Occupied

https://vocab.eona-x.eu/datex-ii/status-occupiedhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The charging point is currently in use by a vehicle.

Available

https://vocab.eona-x.eu/datex-ii/status-availablehttp://www.w3.org/2004/02/skos/core#Concept

Definition
The charging point is operational and free to use.

Charging point status

https://vocab.eona-x.eu/datex-ii/statushttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Operational / availability status of an electric vehicle charging point (e.g. available, occupied, out of service).
Scope note
Value type: enumeration — see narrower code values. Rendered from the DATEX II Facilities availability / OperatingStatus model; the code set is hub-curated to an OCPI-style status list.

Energy provider

https://vocab.eona-x.eu/datex-ii/energyProviderhttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The organisation providing the energy delivered at the station.
Scope note
Value type: object reference (DATEX II Organisation).

No access

https://vocab.eona-x.eu/datex-ii/authMethod-noAccesshttp://www.w3.org/2004/02/skos/core#Concept

Definition
Not accessible / no public access.

Unlimited access

https://vocab.eona-x.eu/datex-ii/authMethod-unlimitedAccesshttp://www.w3.org/2004/02/skos/core#Concept

Definition
Freely accessible; no authentication required.

Prepaid card

https://vocab.eona-x.eu/datex-ii/authMethod-prepaidCardhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Authentication / payment by prepaid card.

Website

https://vocab.eona-x.eu/datex-ii/authMethod-websitehttp://www.w3.org/2004/02/skos/core#Concept

Definition
Authentication via a website.

Apps

https://vocab.eona-x.eu/datex-ii/authMethod-appshttp://www.w3.org/2004/02/skos/core#Concept

Definition
Authentication via a mobile application.

Cash payment

https://vocab.eona-x.eu/datex-ii/authMethod-cashPaymenthttp://www.w3.org/2004/02/skos/core#Concept

Definition
Payment in cash.

Debit card

https://vocab.eona-x.eu/datex-ii/authMethod-debitCardhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Authentication / payment by debit card.

Credit card

https://vocab.eona-x.eu/datex-ii/authMethod-creditCardhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Authentication / payment by credit card.

NFC

https://vocab.eona-x.eu/datex-ii/authMethod-nfchttp://www.w3.org/2004/02/skos/core#Concept

Definition
Identification by Near Field Communication.

RFID

https://vocab.eona-x.eu/datex-ii/authMethod-rfidhttp://www.w3.org/2004/02/skos/core#Concept

Definition
Identification by RFID token / charge card.

Operating hours

https://vocab.eona-x.eu/datex-ii/operatingHourshttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The opening / operating hours during which the site is accessible.
Scope note
Value type: object reference (DATEX II OperatingHours / OverallPeriod), inherited from Facility.

Entrance

https://vocab.eona-x.eu/datex-ii/entrancehttp://www.w3.org/2002/07/owl#ObjectPropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The geographic location of an entrance to the site.
Scope note
Value type: object reference (DATEX II Location).

Brand

https://vocab.eona-x.eu/datex-ii/brandhttp://www.w3.org/2002/07/owl#DatatypePropertyhttp://www.w3.org/2004/02/skos/core#Concept

Definition
The commercial brand of the energy infrastructure site.
Scope note
Value type: xsd:string. DATEX II native type: MultilingualString.